Acoustic Treatment of a Music Venue with a High Level of Internal Noise

Authors

  • Adolfo Scherre Tomazinho Bonisson .
  • Rafael Bassan Gava .
  • Marlon Fernandes Ramos .

Abstract

One of engineering's major aims is to make buildings increasingly sustainable. The search for lighter, more economical, and faster-to-execute solutions grows more intense every day, but brings with it the need for adaptations. The less robust the structures, the worse their comfort conditions and the greater the attention that must be paid to complementary designs intended to make up for that loss. The aim of a building's acoustic design is to provide the necessary conditions for the facility to perform fully from an acoustic standpoint, and to avoid any disturbances generated in its surroundings. For this purpose, solutions for doors, windows, ceilings, walls, and floors, among others, are developed so as to treat the already pre-defined structure, attenuating the noise level—whether internal or external—in accordance with project requirements. It is initially determined that internally an environment is expected to have a maximum noise level of 85 dB, occurring concomitantly and without interfering with that of another, quieter environment of 60 dB, and an external noise level is delimited at 45 dB. With brick walls plastered with mortar at thicknesses of 125 mm and 225 mm, windows with robust frames and glazing thicknesses of 16 mm and 25 mm, acoustic doors, acoustic mineral ceilings, and reinforced concrete slabs 100 mm thick, the project requirements are met. These conditions are based on values indicated in current standards, which—although recently formulated and whose development has been slow compared with American and European standards—are available to guide designers in developing acoustic projects, delimiting safety and comfort limits for various environments. In addition, municipalities have enacted laws to establish penalties for possible negligence with respect to these standards. When the requirements are met, it is guaranteed that the building in question is fit to perform its intended purpose, but it cannot be guaranteed that it will comply with the standards if the design specifications are exceeded. It is therefore the responsibility of the owners to control their premises and of regulatory authorities to inspect them regularly.
Views: 342Downloads: 224

Downloads

Download data is not yet available.

Published

2023-07-25

How to Cite

Bonisson, A. S. T., Gava, R. B., & Ramos, M. F. (2023). Acoustic Treatment of a Music Venue with a High Level of Internal Noise. REMUNOM, 2(1). https://remunom.ojsbr.com/multidisciplinar/article/view/523

Most read articles by the same author(s)