MAGNETIC RESONANCE IMAGING FOR DIFFERENTIATING BENIGN INSUFFICIENCY-RELATED FROM MALIGNANT VERTEBRAL COMPRESSION FRACTURES: A FOCUSED REVIEW AND EXPLORATORY QUANTITATIVE SYNTHESIS

Authors

DOI:

https://doi.org/10.66104/g0h0aw68

Keywords:

magnetic resonance imaging, vertebral compression fracture, insufficiency fracture, malignant vertebral fracture, chemical-shift imaging

Abstract

Vertebral compression fractures caused by osteoporosis or other forms of bone insufficiency may closely resemble fractures produced by malignant marrow replacement. This focused review with exploratory quantitative synthesis evaluated magnetic resonance imaging features used to distinguish benign from malignant vertebral compression fractures and descriptively summarized studies reporting reconstructible accuracy data for chemical-shift or Dixon-based measurements. MEDLINE/PubMed searches, citation tracking, and DOI-directed searches were performed through 14 September 2026. Eligible studies evaluated adults with vertebral compression fractures, used MRI as the index test, and established benign or malignant status through histopathology, clinical and imaging follow-up, or a composite reference standard. Four studies comprising 201 vertebral-level observations, including 83 malignant and 118 benign observations, supplied reconstructible 2 × 2 data for quantitative fat-sensitive MRI. Across studies, sensitivity ranged from 95.0% to 100.0%, with a median of 95.4%, and specificity ranged from 85.7% to 100.0%, with a median of 92.4%. Because of the small number of studies and heterogeneity in techniques, thresholds, reference standards, and analytic units, no pooled meta-analytic estimate was calculated. Conventional signs most consistently associated with malignancy were paraspinal or epidural mass, pedicle or other posterior-element involvement, diffuse marrow replacement, and convex posterior vertebral contour. A band-like marrow pattern, fluid sign, retropulsion of a bone fragment, and healed fractures at other levels favored benignity. Quantitative chemical-shift and Dixon techniques provided useful adjunctive discrimination, but threshold variability, retrospective designs, mixed reference standards, and lesion-level clustering limited certainty. MRI interpretation should integrate morphology, marrow fat, diffusion behavior, and clinical context rather than rely on a single sign.
Views: 456Downloads: 103

Downloads

Download data is not yet available.

Author Biographies

  • Renan, Instituto Goiano de Radiologia - IGR, Brasil

    Graduação em medicina pela ESCS - Brasília (Escola Superior Ciências Saúde)
    Residência em radiologia pelo Hospital Anchieta - Brasília
    Fellow em radiologia músculo esquelética pelo IOG - Goiânia

  • George Harrison, Universidade de Brasília (UnB), Brasil

    Biólogo, enfermeiro, mestre em medicina tropical pela (UFG) e Doutor em Ciências Médicas pela Universidade de Brasília (UnB).

References

Baker, Larry L., et al. “Benign versus Pathologic Compression Fractures of Vertebral Bodies: Assessment with Conventional Spin-Echo, Chemical-Shift, and STIR MR Imaging.” Radiology, vol. 174, no. 2, 1990, pp. 495-502. https://doi.org/10.1148/radiology.174.2.2296658. DOI: https://doi.org/10.1148/radiology.174.2.2296658

Baur, Andreas, et al. “Acute Osteoporotic and Neoplastic Vertebral Compression Fractures: Fluid Sign at MR Imaging.” Radiology, vol. 225, no. 3, 2002, pp. 730-35. https://doi.org/10.1148/radiol.2253011413. DOI: https://doi.org/10.1148/radiol.2253011413

Donners, Ricardo, et al. “Dixon or DWI: Comparing the Utility of Fat Fraction and Apparent Diffusion Coefficient to Distinguish between Malignant and Acute Osteoporotic Vertebral Fractures.” European Journal of Radiology, vol. 132, 2020, article 109342. https://doi.org/10.1016/j.ejrad.2020.109342. DOI: https://doi.org/10.1016/j.ejrad.2020.109342

Erly, William K., E. S. Oh, and Eric K. Outwater. “The Utility of In-Phase/Opposed-Phase Imaging in Differentiating Malignancy from Acute Benign Compression Fractures of the Spine.” American Journal of Neuroradiology, vol. 27, no. 6, 2006, pp. 1183-88.

Kim, Dong Hyun, et al. “Differentiation of Acute Osteoporotic and Malignant Vertebral Fractures by Quantification of Fat Fraction with a Dixon MRI Sequence.” American Journal of Roentgenology, vol. 209, no. 6, 2017, pp. 1331-39. https://doi.org/10.2214/AJR.17.18168. DOI: https://doi.org/10.2214/AJR.17.18168

Mauch, John T., et al. “Review of the Imaging Features of Benign Osteoporotic and Malignant Vertebral Compression Fractures.” American Journal of Neuroradiology, vol. 39, no. 9, 2018, pp. 1584-92. https://doi.org/10.3174/ajnr.A5528. DOI: https://doi.org/10.3174/ajnr.A5528

McInnes, Matthew D. F., et al. “Preferred Reporting Items for a Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement.” JAMA, vol. 319, no. 4, 2018, pp. 388-96. https://doi.org/10.1001/jama.2017.19163. DOI: https://doi.org/10.1001/jama.2017.19163

Ragab, Yasser, et al. “Differentiation of Osteoporotic and Neoplastic Vertebral Fractures by Chemical Shift In-Phase and Out-of-Phase MR Imaging.” European Journal of Radiology, vol. 72, no. 1, 2009, pp. 125-33. https://doi.org/10.1016/j.ejrad.2008.06.019. DOI: https://doi.org/10.1016/j.ejrad.2008.06.019

Thawait, Shrey K., et al. “Research Synthesis: What Is the Diagnostic Performance of Magnetic Resonance Imaging to Discriminate Benign from Malignant Vertebral Compression Fractures?” Spine, vol. 37, no. 12, 2012, pp. E736-E744. https://doi.org/10.1097/BRS.0b013e3182458cac. DOI: https://doi.org/10.1097/BRS.0b013e3182458cac

Vasilevska Nikodinovska, Violeta, et al. “Conventional Radiography and Computed Tomography.” Imaging of Primary Tumors of the Osseous Spine, edited by Mohamed Fethi Ladeb and Filip Vanhoenacker, Springer Nature Switzerland, 2024, pp. 55-84. https://doi.org/10.1007/174_2023_465. DOI: https://doi.org/10.1007/174_2023_465

Whiting, Penny F., et al. “QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies.” Annals of Internal Medicine, vol. 155, no. 8, 2011, pp. 529-36. https://doi.org/10.7326/0003-4819-155-8-201110180-00009. DOI: https://doi.org/10.7326/0003-4819-155-8-201110180-00009

Yilmaz Ovali, Gulgun, et al. “Benign versus Malignant Vertebral Compression, Chemical Shift MR Imaging, Is It Useful?” Iranian Journal of Radiology, vol. 14, no. 2, 2017, article e42016. https://doi.org/10.5812/iranjradiol.42016. DOI: https://doi.org/10.5812/iranjradiol.42016

Yuh, William T. C., et al. “Vertebral Compression Fractures: Distinction between Benign and Malignant Causes with MR Imaging.” Radiology, vol. 172, no. 1, 1989, pp. 215-18. https://doi.org/10.1148/radiology.172.1.2740506. DOI: https://doi.org/10.1148/radiology.172.1.2740506

Published

2026-09-25

How to Cite

Belém, R. M. F. M., & Carvalho, G. H. F. de. (2026). MAGNETIC RESONANCE IMAGING FOR DIFFERENTIATING BENIGN INSUFFICIENCY-RELATED FROM MALIGNANT VERTEBRAL COMPRESSION FRACTURES: A FOCUSED REVIEW AND EXPLORATORY QUANTITATIVE SYNTHESIS. REMUNOM, 13(20), 1-17. https://doi.org/10.66104/g0h0aw68

Similar Articles

1-10 of 50

You may also start an advanced similarity search for this article.