STEEL COLUMNS FINITE ELEMENT BUCKLING ANALYSIS BY OPEN-SOURCE SOFTWARE FreeCAD.

Authors

  • Celisy Grasiela Ribeiro Dias UFOP
  • Geraldo Donizetti de Paula UFOP
  • Flávio Teixeira de Souza IFMG - Campus Ouro Preto

DOI:

https://doi.org/10.61164/t8g39594

Keywords:

Steel columns; linear buckling; finite element method; open-source software; FreeCAD.

Abstract

Steel structures are widely used in buildings that demand rapidity and large free spans, because they are slender, lighter and stronger than concrete structures. This slenderness, however, make these structures prone to buckling, an instability phenomena characterized by columns repentine curvature. In cold-formed structures, there are also local and distortional buckling due to the use o very thin steel plates, that makes, their behavior still more complex. Numerical melhods, as the Finite Element Method, are commonly used to evaluate the strenght and behavior of steel structures. There are commercial Finite Element packages, but their high costs may difficult access by institutions and professionals tho them. An alternative are the open-source software, as FreeCAD. This work analyses the efficience of steel columns bucking analysis by FreeCAD Finite Element workbench. Laminated and cold-formed columns were analized, and Finite Element results were compared to theoretical ones. It was observed good agreement of results. It validades the procedures developed in buckling Finite Element analysis by FreeCAD. That indicates a possibility of costs reduction for institutions and professionals by adoption of FreeCAD for steel structuresfor research and design.

Downloads

Download data is not yet available.

References

ABNT. ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR 14762: Dimensionamento de estruturas de aço constituídas por Perfis Formados a Frio. Rio de Janeiro: ABNT, 2010.

AMERICAN IRON AND STEEL INSTITUTE. AISI-S100-16 (2024). “North American Specification for the Design of Cold-Formed Steel Structural Members”, Washington, D.C., 2024.

BEBIANO, R.; PINA, P.; SILVESTRE, N.; CAMOTIM, D. GBTUL – Buckling and Vibration Analysis of Thin-Walled Members, DECivil/IST, Technical University of Lisbon, 2008. (http://www.civil.ist.utl.pt/gbt).

FreeCAD. Disponível em: https://www.FreeCAD.org/features.php. Acesso em: 125 de outubro de 2025

HANCOCK, G. J., KWON, Y. B., BERNARD, E. S. (1994). Strength design curves for thin-walled sections undergoing distortional buckling. Journal of Constructional Steel Research. 31 (1994) 169-186 DOI: https://doi.org/10.1016/0143-974X(94)90009-4

FERREIRA, G. H., SARMANHO, A. M. C., SOUZA, F. T. Avaliação via método dos elementos finitosda flambagem local em pilares em aço formados a frio do tipo rack com furos com bordas enrijecidas. Revista Brasileira Multidisciplinar, v. 28 n. 2, p. 173-189, 2025. Disponível em: https://revistarebram.com/index.php/revistauniara/article/view/2222

FREITAS, A. M. S., FREITAS, M. S. R., SOUZA, F. T. (2010). Analysis and behavior of steel storage drive-in racks.Thin-Walled Structures, Vol. 48, p. 110-117. DOI: https://doi.org/10.1016/j.tws.2009.09.003. Disponível em: https://www.sciencedirect.com/science/article/abs/pii/S0263823109001992 DOI: https://doi.org/10.1016/j.tws.2009.09.003

GOMES, D. M.; SARMANHO, A. M. C.; SOUZA, F. T.; Análise numérica de pilares formados a friodo tipo rack com perfurações de borda enrijecida. Revista Eletrônica de Engenharia Civil, v. 19 n. 1, p. 78-91, 2023. DOI: https://doi.org/10.5216/reec.v19i1.74342. Disponível em: https://revistas.ufg.br/reec/article/view/74342. DOI: https://doi.org/10.5216/reec.v19i1.74342

JARDIM JR, F.; HELENO, R. P.; SOUZA, F. T.; SARMANHO, A. M. C. Estudo da viabilidade do método da Resistência Direta em Perfis U enrijecidos formados a frio com perfurações. Revista Eletrônica de Engenharia Civil, v. 17 n. 1, p. 1-15, 2021. DOI: https://doi.org/10.5216/reec.v17i1.56289. Disponível em: https://revistas.ufg.br/reec/article/view/56289.

MOEN, C. D.; SCHAFER, B. W. Direct strength method for design of cold-formed steel columns withholes. Journal of Structural Engineering, v. 137, n. 5, p. 559-570, 2011. DOI: https://doi.org/10.1061/(ASCE)ST.1943-541X.0000310

NEIVA, L. H. A.; SALES, A. E. C. A.; ELIAS, G. C.; SARMANHO, A. M. C.; SOUZA, F. T. Análise do modo distorcional de elementos perfurados segundo Método da Resistência Direta. Revista da Estrutura de Aço. v. 7. p. 17-36, 2018. DOI: https://doi.org/10.17648/aco-2238-9377-7-1-2

NICOLAU, I. A. N.; SARMANHO, A. M. C.; SOUZA, F. T. Análise Numérica de Perfis Formados a Frio do tipo U Enrijecido com Perfurações Enrijecidas Submetidos à Compressão. Revista de Engenharia e Pesquisa Aplicada, v. 8, n. 2, p. 1-10, 2023. DOI: https://doi.org/10.25286/repa.v8i2.2193. Disponível em: http://revistas.poli.br/index.php/repa/article/view/2193. DOI: https://doi.org/10.25286/repa.v8i2.2193

OLIVEIRA, L. C. P.; SARMANHO, A. M. C.; SOUZA, F. T. Análise da influência das dimensões das perfurações em pilares compostos por perfis em aço formados a frio do tipo U enrijecido. Revista de Engenharia e Pesquisa Aplicada, v. 7, n. 1, p. 30-37, 2022. DOI: 10.25286/repa.v7i1.1717. Disponível em: http://revistas.poli.br/index.php/repa/article/view/1717 DOI: https://doi.org/10.25286/repa.v7i1.1717

PEREIRA, A. F. N.; SARMANHO, A. M. C., SOUZA, F. T. Análise via Elementos Finitos de Pilares em Perfis Formados a Frio do tipo U enrijecido com perfurações submetidos à flambagem distorcional. REUCP, Petrópolis, v. 17, n. 1, 85-98, 2023. Disponível em: https://seer.ucp.br/seer/index.php/REVCEC/article/view/2646

PINTO, R. A. R.; SARMANHO, A. M. C.; SOUZA, F. T. Análise Numérica da influência das dimensões e posição das perfurações na resistência à instabilidade distorcional de perfis formados a frio do tipo rack comprimidos. Revista da Estrutura de Aço. v. 10. p. 333-350, 2021. DOI: https://doi.org/10.70271/250507.102503

SALMON, C. G.; JOHNSON, J. E. STEEL STRUCTURES-DESIGN AND BEHAVIOUR. 1990.

SANTOS, E. T.;; SARMANHO, A. M. C.; SOUZA, F. T. Análise numérica da influência das dimensões de perfurações em perfis formados a frio do tipo rack submetidos à compressão. Revista Mundi Engenharia, TecnologiaeGestão,Paranaguá,PR,v.5,n.5,p.1-266,2020.DOI:10.21575/25254782rmetg2020vol5n51128. Disponível em: https://periodicos.ifpr.edu.br/index.php/MundiETG/article/view/1128. DOI: https://doi.org/10.21575/25254782rmetg2020vol5n51128

SCHAFFER, B., YU, C. (2006). Distortional buckling tests on cold-formed steel beams. Journal of Structural Engineering 132 (2006) 515-528. DOI: https://doi.org/10.1061/(ASCE)0733-9445(2006)132:4(515)

SCHARDT, R. (1994). Generalized Beam Theory – An Adequate method for Coupled Stability Problems. Thin-Walled Structures, 19, p. 161-180. DOI: https://doi.org/10.1016/0263-8231(94)90027-2

Published

2025-10-30

How to Cite

STEEL COLUMNS FINITE ELEMENT BUCKLING ANALYSIS BY OPEN-SOURCE SOFTWARE FreeCAD. (2025). Revista Multidisciplinar Do Nordeste Mineiro, 19(03), 1-18. https://doi.org/10.61164/t8g39594