Advantages and Disadvantages of the Use of Glass Fiber in Reinforced Concrete: A Literature Review

Authors

  • Bruna Vieira De Souza IESC/FAG Faculdade Guaraí
  • Jonathan Mendes da Silva UFSCar
  • Karla Cristina Bentes Moreira UFSCar
  • Shara Carvalho Lopes Federal University of São Carlos image/svg+xml

DOI:

https://doi.org/10.61164/rmnm.v11i1.1645

Keywords:

concreto armado, fibra de vidro, resistência à corrosão, propriedades mecânicas, vantagens e desvantagens, estruturas de grande porte

Abstract

The construction industry constantly seeks innovative materials to improve the strength and durability of structures. Reinforced concrete, widely used, has been the subject of studies concerning deterioration and the emergence of pathological manifestations. In this context, glass fiber emerges as an alternative to replace steel, offering favorable mechanical properties such as high tensile strength and corrosion resistance, lightness, and electromagnetic neutrality. However, the use of glass fiber in large-scale structures and under high loads still requires further studies and experimental tests to ensure its safety and performance. Compared to steel, glass fiber reinforcements present advantages such as high resistance to corrosion, fatigue, and fire. However, they have disadvantages such as dimensional stability and the requirement for specialized labor. The objective of this work is to conduct a literature review to compare the characteristics and properties of glass fiber and steel in reinforced concrete, highlighting their advantages and disadvantages. The methodology used included a search for up-to-date information in books, scientific articles, and theses, with a qualitative analysis of the collected data. The results indicated that the use of glass fiber in construction can indeed be advantageous for certain types of structures, such as constructions in aggressive and corrosive environments, but, like any material, it has disadvantages; the glass fiber–reinforced polymer (GFRP/PRFV) would be no different, and its use may therefore be limited to certain situations and exposures.
Views: 2636Downloads: 295

Downloads

Download data is not yet available.

References

ABBOOD, I. S.; ODAA, S. A.; HASAN, K. F.; JASIM, M. A. PROPERTIES EVALUATION OF FIBER REINFORCED POLYMERS AND THEIR CONSTITUENT MATERIALS USED IN STRUCTURES – A review. Materials Today: Proceedings, 43, 1003–1008, (2021). Disponível em: https://doi.org/10.1016/J.MATPR.2020.07.636. Acesso em 14 de jun. 2023. DOI: https://doi.org/10.1016/j.matpr.2020.07.636

AMERICAN CONCRETE INSTITUTE. Guide For The Design And Construction Of Structural Concrete Reinforced With Frp Bars (ACI 440.1R-2015). Nova York, EUA, 2015.

ANDRADE, A. L. (2017). Utilização de fibra de vidro em estruturas. Revista Brasileira de Engenharia Civil, v. 2, n. 1, p. 13-22.

BANTHIA, N. FIBER REINFORCED CONCRETE. Vancouver: University of British Columbia. 2009.

BEBER, A. J. (2003). COMPORTAMENTO ESTRUTURAL DE VIGAS DE CONCRETO ARMADO REFORÇADAS COM COMPÓSITOS DE FIBRA DE CARBONO. Porto Alegre: CPGEC / UFRGS, Tese de doutorado.

CATEB Lucas Carvalho et al. Universidade Federal de Minas Gerais (UFMG): CONCRETO COM ARMADURA DE FIBRA DE VIDRO.2011. Disponível em: http://hdl.handle.net/1843/BUOS-9CAFPY.

GONÇALVES, C. S. ANÁLISE DO COMPORTAMENTO DE ESTRUTURAS DE CONCRETO ARMADO COM ARMADURAS DE FIBRA DE VIDRO. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Minas Gerais, Belo Horizonte, 2018.

GONÇALVES, F. C. (2018). APLICAÇÕES DE ARMADURAS DE FIBRA DE VIDRO EM ESTRUTURAS DE GRANDE PORTE. Revista Brasileira de Engenharia Civil, v. 18, n. 1, p. 53-62.

GONÇALVES, M. A. CONCRETO ARMADO COM FIBRA DE VIDRO: UMA REVISÃO DAS VANTAGENS E DESVANTAGENS. In: Congresso brasileiro de engenharia civil, 8., 2018, Belo Horizonte. Anais... Belo Horizonte: UFMG, 2018.

JOHNSON, A. B. (2019). MÉTODOS DE PESQUISA EM CIÊNCIAS SOCIAIS. Editora X.

LEE, S.; PARK, J.; KIM, M. (2021). IMPORTANCE OF LITERATURE REVIEW IN RESEARCH WRITING. Journal of Educational Evaluation for Health Professions, 18, 1-5.

MARTINS, A. A. ARMADURAS DE FIBRA DE VIDRO EM ESTRUTURAS DE CONCRETO ARMADO. Revista Técnico-Científica de Engenharia Civil, v. 5, n. 1, p. 67-74, 2013.

MARTINS, L. C. (2013). FIBRA DE VIDRO PARA CONCRETO ARMADO. São Paulo: ABCM.

MENON, N. V.; RISSON, A. V.; ARCINE, M. F. SISTEMA DE ANCORAGEM POR CORDÃO DE FIBRAS DE CARBONO EM VIGAS REFORÇADAS À FLEXÃO COM PRFC -estudo experimental. Brazilian Journal of Development, [S. l.], v. 6, n. 1, p. 4303–4308, 2020. DOI: https://doi.org/10.34117/bjdv6n12-680

OLIVEIRA, D. C. DESEMPENHO DE ARMADURAS DE FIBRA DE VIDRO EM ESTRUTURAS DE CONCRETO ARMADO. Monografia (Especialização em Estruturas de Concreto Armado e Protendido) - Universidade Federal do Paraná, Curitiba, 2015.

OLIVEIRA, R. V. ANÁLISE DAS VANTAGENS E DESVANTAGENS DA UTILIZAÇÃO DE ARMADURAS DE FIBRA DE VIDRO EM ESTRUTURAS DE CONCRETO ARMADO. In: Congresso Brasileiro de Engenharia civil, 7., 2015, Brasília. Anais... Brasília: UnB, 2015.

RAMESH, B.; ESWARI, S.; SUNDARARAJAN, T. FLEXURAL BEHAVIOUR OF GLASS FIBRE REINFORCED POLYMER (GFRP) LAMINATED HYBRID-FIBRE REINFORCED CONCRETE BEAMS. SN Applied Sciences, 2(2), 204, 2020. Disponível em: https://doi.org/10.1007/s42452-020-1966-2. Acesso em 14 de jun. 2023. DOI: https://doi.org/10.1007/s42452-020-1966-2

SANTOS Diego Benner Freire et al. ESTUDO COMPARATIVO ENTRE OS VERGALHÕES DE AÇO E POLÍMERO REFORÇADO COM FIBRA DE VIDRO. 2022. Disponível em: https://repositório.animaeduccao.com.br/handle/ANIMA/24880.

SANTOS, E. M. COMPORTAMENTO DAS ARMADURAS DE FIBRA DE VIDRO EM ESTRUTURAS DE CONCRETO ARMADO. Dissertação (M estrado em Engenharia Civil) - Universidade de São Paulo, São Paulo, 2010.

SANTOS, L. R. AS ARMADURAS DE FIBRA DE VIDRO E SUAS PROPRIEDADES MECÂNICAS. São Paulo: Universidade de São Paulo, 2010. Dissertação de Mestrado.

SILVA, B. C. UtILIZAÇÃO DE ARMADURAS DE FIBRA DE VIDRO EM ESTRUTURAS DE CONCRETO ARMADO. Monografia (Graduação em Engenharia Civil) - Universidade Estadual de Campinas, Campinas, 2019.

SILVA, F. B. VERGALHÃO DE FIBRA DE VIDRO EM ESTRUTURAS DE CONCRETO ARMADO. In: Simpósio Brasileiro de Estruturas, 21., 2019, Belém. Anais... Belém: UFPA, 2019.

SILVA, M. C.; SANTOS, J. R.; OLIVEIRA, A. B.; SOUZA, F. A. (2020). ÉTICA NA PESQUISA CIENTÍFICA: UM GUIA PARA PESQUISADORES INICIANTES. Revista Brasileira de Pesquisa Científica, 12(1), 45-51. DOI: https://doi.org/10.6008/CBPC2179-684X.2020.003.0004

SINGH, R.; SINGH, D. (2021). FIBRE REINFORCED POLYMER COMPOSITES FOR CONSTRUCTION APPLICATIONS: A review. Composites Part B: Engineering, v. 211, p. 108542.

SMITH, R.; JONES, T.; WILLIAMS, L. (2017). QUALITATIVE DATA ANALYSIS: A PRACTICAL EXAMPLE. Journal of Applied Research in Higher Education, 9(2), 341-356.

TAVARES, P. M. VERGALHÃO DE FIBRA DE VIDRO E SUAS APLICAÇÕES EM ESTRUTURAS DE CONCRETO ARMADO. In: Encontro Nacional de Tecnologia do Ambiente Construído, 12., (2017), Fortaleza. Anais... Fortaleza: UFC, 2017.

WITT, C. FIBER REINFORED COMPOSITE. (2009). Toronto: University of Toronto.

ZANOTTI, R. A.; DIAS, M. A. V. C. (2018). ASPECTOS TÉCNICOS, ECONÔMICOS E AMBIENTAIS DE VIGAS DE CONCRETO REFORÇADAS COM FIBRA DE VIDRO. Revista Matéria, v. 23, n. 2, p. e12781.

Published

2023-09-28

How to Cite

Vieira De Souza, B., Mendes da Silva, J., Bentes Moreira, K. C., & Carvalho Lopes, S. (2023). Advantages and Disadvantages of the Use of Glass Fiber in Reinforced Concrete: A Literature Review. REMUNOM, 11(1). https://doi.org/10.61164/rmnm.v11i1.1645

Similar Articles

1-10 of 50

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)